Refrigerating equipment of a broad field of application Rambler's Top100

Code

Technical characteristics of the equipment. Technological application.

Price,

USD

11BW1

 

Quick – freezing rotor unit. Type RZ – FYZ.

It is designed for food products, such as fish, fish products, meat, meat products, curds, shredded vegetable freezing. Products are packed into polyethylene package beforehand. Product freezing is in the form of blocks.

Technical capacity (fish-and-meat freezing) – 600 kg per h.

Temperature of refrigerated product (fish): -12 oC .

Dimensions of refrigerated blocks – 370΄ 370΄ 75 mm.

Weight of refrigerated blocks – 10 kg.

Freezing time – 2.2 h.

Number of freezing sections – 21 pieces.

Refrigerant agent – liquid ammonia.

Electric power consumption – 1.8 kW per h.

33600

11BJ2 Heating refrigerating machine 11 FH 50-2-0 for fruit storehouses.

It is designed for creation and automatic maintenance of necessary temperature condition (from – 2 to + 4oC) in a compartment (a chamber) of fruit storehouses.

A list of the components will be presented upon receipt of the inquiry.

upon receipt of the inquiry.
11AT1 Refrigerant compressors
Mark Purpose Type Working range Coolant Main characteristics
 

Refrigerating capacity, kW

( Kcal/h )

Power consumption in standard mode, kW
 

a.

1P10-2-02 For operation in stationary and transport refrigerating plants  

Piston vertical single-stage open-type

Boiling temperature, oC 10 to –40; Condensing temperature not more than 50oC  

R22

12.5 ( 10750 )

under conditions

to=-15 oC

tk= 30 oC

4.22
b.  

1P10-4-0

the same the same Boiling temperature, oC 20 to –5; Condensing temperature not more than 85oC  

R142

6.8 ( 5848 )

under conditions

to= 5oC

tk= 60oC

2.73
c.  

11P10-2-4

For operation in stationary double-stage and cascade plants  

Piston vertical low-temperature open-type

Boiling temperature, oC -10 to –50; Condensing temperature not more than 50oC  

R22

13.4 ( 11524 )

under conditions

to= -15oC

tk= 30oC

4.22
d. 11P10-3-4  

the same

the same Boiling temperature, oC - 70 to –100; Condensing temperature not more than 20oC  

R13

1.83 ( 1756 )

under conditions

to = - 90oC

tk = - 30oC

2.2
e. 1P20-2-02  

For operation in stationary and transport refrigerating plants

 

Piston V-shape single-stage open-type.

Boiling temperature, oC 10 to –40; Condensing temperature not more than 50oC  

R22

25 ( 21500 )

under conditions

to = - 15oC

tk = 30oC

8.5
f.  

1P20-4-0

the same the same Boiling temperature, oC 20 to –5; Condensing temperature not more than 85oC  

R 142

13.75 ( 11825 )

under conditions

to = 5oC

tk = 60oC.

5.46
g.  

11P20-2-4

For operation in stationary and transport refrigerating plants  

Piston V-shape single-stage open-type.

Boiling temperature, oC - 10 to –50; Condensing temperature not more than 50oC  

R22

26.8 ( 23018 )

under conditions

to = - 15oC

tk = 30oC

8.5
h.  

11P20-3-4

For operation in stationary double-stage and cascade plants  

the same

Boiling temperature, oC - 70 to –100; Condensing temperature not more than 20oC  

R13

3.5 ( 3360 )

under conditions

to = - 90oC

tk = - 30oC

4.44
i. 5PB7-2-024 Designed for operations as a part of the automated stationary and transport refrigerating plant and air conditioners.  

Piston semihermetic with build-in electric motor.

Boiling temperature, oC - 40 to 5; Condensing temperature not more than 50oC  

R22

8.6 ( 7396 )

under conditions

to = - 15oC

tk = 30oC

3.07
j. 5PB7-4-0 the same the same Boiling temperature, oC - 5 to 20; Condensing temperature not more than 85oC  

R142

4.49 ( 3861 )

under conditions

to = 5oC

tk = 60oC

1.96
k. 5PB10-2-024 the same the same Boiling temperature, oC - 40 to 5; Condensing temperature not more than 50oC  

R22

13.4 ( 11524 )

under conditions

to = -15oC

tk = 30oC

4.8
l. 5PB10-4-0 the same the same Boiling temperature, oC - 5 to 20; Condensing temperature not more than 85oC  

R142

7.16 ( 6157 )

under conditions

to = 5oC

tk = 60oC

3.11
m. 5PB14-2-024 the same the same Boiling temperature, oC - 40 to 5; Condensing temperature not more than 50oC  

R22

16.8 ( 14448 )

under conditions

to = -15oC

tk = 30oC

5.8
n. 5PB14-4-0 the same the same Boiling temperature, oC - 5 to 20; Condensing temperature not more than 85oC  

R142

9.31 ( 8006 )

under conditions

to = 5oC

tk = 60oC

3.93
o. 5PB20-2-024 the same the same Boiling temperature, oC - 40 to 5; Condensing temperature not more than 50oC  

R22

24.4 ( 20984 )

under conditions

to = -15oC

tk = 30oC

8.8
p. 5PB20-4-0 the same the same Boiling temperature, oC - 5 to 20; Condensing temperature not more than 85oC  

R142

13.68 ( 11764 )

under conditions

to = 5oC

tk = 60oC.

5.78
q. 5PB36-2-024 the same the same Boiling temperature, oC - 40 to 5; Condensing temperature not more than 50oC  

R22

36.2 ( 31130 )

under conditions

to = -15oC

tk = 30oC

11.3
r.  

5PB36-4-0

the same the same Boiling temperature, oC - 5 to 20; Condensing temperature not more than 85oC  

R142

18.35 ( 15780 )

under conditions

to = 5oC

tk = 60oC.

960
s. 5PB50-2-024 the same the same Boiling temperature, oC - 40 to 5; Condensing temperature not more than 50oC  

R22

50.0 ( 43000 )

under conditions

to = -15oC

tk = 30oC

15.62
t. 5PB50-4-0 the same the same Boiling temperature, oC - 5 to 20; Condensing temperature not more than 85oC  

R142

26.87 ( 23100 )

under conditions

to = 5oC

tk = 60oC.

9.76
u.  

4PBD3-2-4

( 5PBD3-2-4 )

 

For operation as a part of the automated low-temperature refrigerating machines.

 

Piston double-stage low-temperature semihermetic.

Boiling temperature, oC - 60 to - 40; Condensing temperature not more than 50oC  

R22

3.2 ( 2750 )

under conditions

to = - 60 oC

tk = 30oC.

3.6
v. 4PBD5-2-4

( 5PBD5-2-4 )

the same the same the same R22 5.0 ( 4300 )

under conditions

to = - 60 oC

tk = 30oC.

5.6
Code General industrial purpose condensing unit

11AT2

Mark Name Purpose Working range Basic characteristics
 

Refrigerating capacity, kW

( Kcal/h )

 

Power consumption at nominal conditions, kW.

a. AK7-2-0 Condensing unit with water-cooled condenser For refrigerating supply of self-contained air conditioners and other equipment, where evaporator and electrical devices are selected and mounted by customer. Boiling temperature

-15 to 5oC;

water temperature 1 to 33oC.

17.0 ( 14600 )

( at boiling temperature 5oC, water temperature at condenser inlet 25oC, water flow rate 2.8

m3/hr ).

Coolant – R22

4.65
b. AK7-1-2 the same For centralized refrigerating supply of commercial display counter and other equipment, where evaporator and electrical devices are selected and mounted by customer Boiling temperature

-30 to - 5oC;

water temperature 1 to 33oC.

5.06 ( 4350 )

( at boiling temperature

– 15oC, water temperature at condenser inlet 20oC, water flow rate 0.8 m3/h ).

Coolant – R12

 

2.02

c. A7-2-2 the same the same Boiling temperature

-40 to - 5oC;

water temperature 1 to 33oC.

7.0 ( 6000 )

( at boiling temperature

– 15oC, water temperature at condenser inlet 20oC, water flow rate 0.8 m3/h ).

Coolant – R22

3.3
d. AK10-1-2 the same the same Boiling temperature

-30 to - 5oC;

water temperature 1 to 33oC.

7.21 ( 6200 )

( at boiling temperature

– 15oC, water temperature at condenser inlet 20oC, water flow rate 0.8 m3/h ).

Coolant – R12

2.95
e. AK9-1-2 Condensing unit with air-cooled condenser the same According to boiling temperature

-30 to - 5oC;

water temperature 1 to 33oC.

10.5 ( 9000 )

( at boiling temperature

– 15oC, water temperature at condenser inlet 20oC, water flow rate 1.3 m3/h ).

Coolant – R12

4.2
f. AK9-2-2 the same the same According to boiling temperature

-40 to - 5oC;

cooling water temperature 1 to 33oC.

11.5 ( 9800 )

( at boiling temperature

– 15oC, water temperature at condenser inlet 20oC, water flow rate 1.3 m3/h ).

Coolant – R12

1.3
g. AK4.5-2-4 the same the same Boiling temperature

-40 to - 20oC;

water temperature 1 to 33oC.

5.4 ( 4650 )

( at boiling temperature

– 30oC, water temperature at condenser inlet 20oC, water flow rate 0.8 m3/h ).

Coolant – R22

3.4
h.  

AKD5-2-4

Condensing unit with double-stage compressor and water-cooled condenser For operation as a part of low-temperature refrigerating machine MKVD5-2-4 type and other low-temperature equipment. Boiling temperature

up to –60oC;

water temperature at condenser inlet up to 33oC.

4.53 ( 3900 )

( at boiling temperature

-60oC, condensation point 30oC ).

Coolant – R22

6.3
i. AV7-2-0 Condensing unit with air-cooled condenser For operation as a port of system of cooling milk MKA-type

and other equipment.

Boiling temperature 10 to –15oC, cooling air temperature 5 to 40oC.  

10.8 ( 9300 )

( at boiling temperature

-5oC, air temperature at condenser inlet 25± 3oC ).

Coolant – R22

 

3.07

j. 1AV7-2-0 the same the same the same the same 3.07
k. 2AV7-2-0 the same For change old equipment, which operated with R12 Boiling temperature 10 to –15oC, ambient

temperature 5 to 40oC

10.8 ( 9300 )

( at boiling temperature

-5oC, air temperature at condenser inlet 25± 3oC ).

Coolant – R22

3.07
l. AV10-1-0 the same For operation as a part of system of cooling milk MKA-type and other equipment the same 9.3 ( 8000 )

( at boiling temperature

-5oC, air temperature at condenser inlet 30oC ).

Coolant – R12

4.65
m. 1AV10-1-0 the same For operation as a part of system of cooling milk MKA-type and other equipment with coolant pumping out from evaporator vessel. the same the same 4.65
n. 1AV6-1-2 the same For centralized refrigerating supply of commercial display counter and other equipment, where evaporator and electrical devices are selected and mounted by customer . According to boiling temperature -10 to

-25oC, ambient air temperature 5oC to 40oC.

7.0 ( 6000 )

( at boiling temperature

-15oC, air temperature at condenser inlet 20oC ).

Coolant – R12

3.11
o. 1AV6-2-2 the same the same According to boiling temperature -40 to

-10oC, ambient air temperature 5oC to 40oC.

 

the same

Coolant – R22

3.34
p. AV9-1-2 the same the same According to boiling temperature -25 to

-10oC, ambient air temperature 5oC to 40oC.

10.5 ( 9000 )

( at boiling temperature

–15oC, air temperature at condenser inlet 20oC ).

4.7
q. AV9-2-2 the same the same According to boiling temperature –40 to

-10oC, ambient air temperature 5oC to 40oC.

11.5 ( 9800 )

( at boiling temperature

-15oC, air temperature at condenser inlet 20oC ).

4.65
r. VP18X2-1-2-01-000 the same For operation as a part of mean-temperature refrigerating machines. According to boiling temperature –40oC to 0oC. Ambient temperature 5oC to 40oC. Mode 1

26.6 ( 22800 )

( at chamber temperature 5oC, air temperature at condenser inlet 35oC ).

Mode 2

14 ( 12000 )

( at chamber temperature

-19oC, air temperature at condenser inlet 35oC ).

Coolant – R12

23.7
s. 2A1000-2-1

2A1000sh-

-2-1

Motor-compressor unit with screw compressor. Designed for operation as a part of refrigerating plants of general industrial and mine construction Boiling temperature – 0oC to –15oC 1000

( at boiling temperature to=0oC, condensing temperature tk=40oC ).

Coolant – R22

300
11AT3 Marine condensing units and refrigerating plants
a. 21AK7-2-3 Marine condensing unit For operation as a part of the refrigerating plants Boiling temperature

-40oC to 5oC.

8.14 ( 7000 )

( at boiling temperature from –15oC, cooling water temperature 30oC, cooling water flow rate 3.5 m3/h ).

Coolant – R22

3.2
b. 21AK10-2-3 the same the same the same 12.0 ( 10250 )

( at boiling temperature from –15oC, cooling water temperature 30oC, cooling water flow rate 4.5 m3/h ).

Coolant – R22

4.4
c. 21AK14-2-3 the same the same the same 17.0 ( 14620 )

( at boiling temperature –15oC, condensing temperature 30oC, cooling water flow rate 6.5 m3/h ).

Coolant – R22

6.2
d. 22AK35-2-4

( OM4 )

( UZ )

Condensing unit For operation as a part of the freezing slab apparatus AMP-type on the fishing ships

( OM4 ) and on the shore for the national economy needs.

Boiling temperature

-40oC to –20oC, ambient air temperature 5 to 45oC.

13.4 ( 11500 )

( at boiling temperature

–35oC, cooling water temperature 28oC, cooling water flow rate 9 m3/h ).

Coolant – R22

10.3
e. 21AK70

( OM4 )

( UZ )

the same For operation as a part of the freezing slab apparatus on the fishing ships ( OM4 ) and on the shore for the national economy needs. Boiling temperature

-40oC to –20oC.

26.7 ( 23500 )

at boiling temperature

–35oC, cooling water temperature 28oC, cooling water flow rate 18m3/h.

Coolant – R22.

20.6
f. MAKB20΄ 2 Marine condensing unit. For operation as a part of the marine refrigerating plants. Boiling temperature

-40oC to –5oC, ambient temperature 5 to 45oC.

42.5 ( 36500 )

at boiling temperature

–15oC, cooling water temperature 30oC, cooling water flow rate 16m3/h.

Coolant – R22.

18.3
g. MAKB35-2-4

( OM4 )

( UZ )

the same For operation as a part of the marine refrigerating plants

( OM4 ) and on the shore for the national economy needs.

the same 41.86 ( 36000 )

at boiling temperature

–15oC, cooling water temperature 30oC, cooling water flow rate 16m3/h.

Coolant – R22.

21.0
h. MAKB35΄ 2

( OM4 )

( UZ )

the same the same Boiling temperature

-40oC to –15oC when two compressors work, -40oC to 5oC when one compressor work. Ambient temperature 5oΡ to 45oΡ.

83.7 ( 72000 )

at boiling temperature

–15oC, suction temperature 20oC, cooling water temperature 30oC, cooling water flow rate 20m3/h.

Coolant – R22.

42.0
i. VF-3M/1-2 Refrigerating plants. For producing and maintaining designed temperature when storage of the perishable foodstuffs in the marine provision chambers. Boiling temperature

-40oC to 5oC, ambient temperature 5oC to 45oC.

2.32 ( 2000 )

at boiling temperature

–15oC, cooling water temperature 30oC, cooling water flow rate 0.7m3/h.

Coolant – R22.

1.7
j. AMK-10PC-1 Marine self-contained air conditioners. For cooling and ventilation of the return air in the rooms. Ambient air temperature 0 to 40oC, sea-water temperature at the air conditioner inlet –2oC to +32oC.  

11.6 ( 10000 )

at boiling temperature

2Έ 6oC,air temperature at the inlet 30oC, kind of current-direct, cooling water flow rate 4.0 m3/h.

Coolant – R12.

7
k. UFP-2 Marine refrigerating plant. For air cooling in provision chambers. Ambient air temperature +5oC to +40oC, seawater temperature at air conditioner inlet

–2oC to +32oC.

Mode 1:

2.3 ( 2000 ) at boiling temperature –15oC, condensing temperature 30oC and compressor shaft rotational speed 420 r.p.m.

4.6 ( 4000 ) at 850 r.p.m.

Mode 2:

4.6 ( 4000 ) at boiling temperature +5oC, condensing temperature 35oC and compressor shaft rotational speed 420 r.p.m.

9.3 ( 8000 ) at 850 r.p.m., direct current.

Coolant – R12

2.2 to 3.9
11AT4 Reversing compressor units.
Code Mark Name Purpose Working range Basic characteristics
a. AKP-12 Reversing compressor unit  

For operation as a part of the refrigerating machines

At boiling temperature –40oC to 10oC. Receiver capacity 12 l. In correspondence with compressor 5PB7 charts.
 

b.

AKP-12-01 the same the same the same In correspondence with compressor 5PB10 charts.
 

c.

AKP-15 the same the same At boiling temperature –40oC to 10oC. Receiver capacity 15 l. In correspondence with compressor 5PB14 charts.
 

d.

AKP-15-01 the same the same the same In correspondence with compressor 5PB20 charts.
 

e.

AKP-87 the same the same At boiling temperature –40oC to 10oC. Receiver capacity 87 l In correspondence with compressor 5PB36 charts.
 

f.

AKP-87-01 the same the same the same In correspondence with compressor 5PB50 charts.
11AT7 Refrigerating chambers and cabinets.
 

Code

 

Mark

Name Purpose Working range Basic characteristics  

Net mass kg

Overall dimensions length, mm

width, mm

height, mm

Temperature range, oC  

Power consumption at nominal conditions kW

 

a.

KX6.00 Collapsible chamber with 1MVV3-2-2 type refrigerating machine.  

For storage of food and other products.

Standard loading 600 kg. Chamber inner capacity 6m3.

Ambient air temperature 5 to 40oC Temperature range in the chamber

–12 to 5oΡ

1,9 1430 1990΄

1990΄

2300

b.  

KX6.00-01

Collapsible chamber with MVV3-2-2 type refrigerating machine.  

the same

the same Temperature range in the chamber

–15 to 5oΡ

2.4 1350 the same
c. KX6.00-02 Collapsible chamber with 1MH1-2-4 type refrigerating machine.  

the same

Ambient air temperature 5 to 32oC Temperature range in the chamber

–9 to -15oΡ

2.1 1330 the same
d. KX12.00 Collapsible chamber with refrigerating machine.  

For storage of food and other products.

Standard loading 1200 kg. Chamber inner capacity 12m3.

 

the same

Temperature range in the chamber

–10 to 5oΡ

1.9 1810 3460΄

1990΄

2300

e. KX12.00-01  

the same

the same the same Temperature range in the chamber

–15 to 5oΡ

 

2.4

1730 the same
f. KX12.00-02 Collapsible chamber with 1MH1-2-4 type refrigerating machine.  

the same

the same Temperature range in the chamber

–5 to -15oΡ

 

2.1

1710 the same
g. KX16.00 Collapsible chamber with 35MVV6-2-2 type refrigerating machine.  

For storage of food and other products.

Standard loading 1800 kg. Chamber inner capacity 16m3.

 

Ambient air temperature 5 to 40oC

Temperature range in the chamber

–18 to 5oΡ

 

3.85

3410 4930΄

1990΄

2300

h. KX16.00-01 Collapsible chamber with 27MVV6-2-2 type refrigerating machine.  

the same

the same the same 3.34 2590 the same
i. KX16.00-02 Collapsible chamber with MVV3-2-2 type refrigerating machine.  

the same

the same Temperature range in the chamber

0 to 15oΡ

 

2.4

2310 the same
j. KX16.00-03 Collapsible chamber with 1MH1-2-4 type refrigerating machine.  

the same

Ambient air temperature 5 to 32oC Temperature range in the chamber

-12 to -15oΡ

 

4.2

2520 the same
k. KX16.00-04 Collapsible chamber with 24MVV10-2-4 type refrigerating machine.  

the same

the same Temperature range in the chamber -12 to

-20oC.

4.4 2690 the same
l. 1H1-0664 Refrigerating cabinet with monoblock refrigerating machine 1MH1-2-4 or 2MH1-2-4 type. For storage of foodstuffs. Cabinet inner capacity 2.7 m3. the same Temperature range in the chamber

-5 to -20oΡ

 

2.1

1000 2780΄

1000΄

1890

m. ShXH-2-01.00 Low-temperature refrigerating cabinet with 1MH1-2-4 type monoblock refrigerating machine.  

For storage of perishable foodstuffs.

Cabinet inner capacity 2.7 m3.

the same Temperature range in the chamber

-10 to -20oΡ

 

2.1

830 2235΄

1045΄

2070

11AT8 Self-contained air conditioners.
 

Code

 

Mark

Name Purpose Working range Basic characteristics.
 

Refrigerating capacity, kW ( Kcal/h )

 

Power consumption at nominal conditions kW.

 

a.

KM7 Self-contained air conditioner for metallurgic cranes. Designed for maintenance of specified temperature conditions in crane cabins of metallurgic plants under defined ceiling ambient temperature.  

Air conditioner working range in cooling mode according to entering air temperature:

-into condenser

40oC to 60oC;

-into air cooler

20oC to 40oC.

Kind of current – alternating.

Voltage:

-power circuit 380 V;

-control circuit 220 V.

 

10kW.

at ambient air temperature at condenser inlet 60oC, air temperature at air cooler inlet 38oC, relative humidity 50%.

Coolant – R142.

11 kW.
b. KM7 PC the same the same Kind of current – constant.

Voltage:

-power circuit 220 V;

-control circuit 220 V.

 

the same

11kW.
c. KK3-1 the same the same Air conditioner working range in cooling mode according to entering air temperature:

-into condenser

40 to 60oC

-into air cooler

27 to 40oC.

Kind of current – alternating.

 

3.5 kW.

at ambient air temperature at condenser inlet 60oC, air temperature at air cooler inlet 32oC, relative humidity 50%.

Coolant – R142.

4.5 kW.
d. KK3-2 the same the same the same the same 4.7 kW.
e.  

KA1-25

Self-contained air conditioner Designed for all the year round comfort air conditioning, used for cooling, heating, humidification and air purification from dust in industrial buildings.  

Ambient air temperature 5 to 40oC, water temperature at condenser inlet up to 33oC, air temperature at air conditioner inlet not less than 18oC.

29.1 kW

at air temperature at air conditioner inlet 27oC, water temperature at condenser inlet 25oC, water flow rate 6 m3/h. Air flow rate through air cooler 6000 m3/h. Heating capacity 25.5 kW.

Coolant – R22.

 

11.4 kW

f. 2KCA-25 the same the same the same the same 11.4 kW.
 

g.

2KCA-45 Self-contained air conditioner  

the same

Ambient air temperature 5 to 40oC, water temperature at condenser inlet up to 33oC, air temperature at air conditioner inlet in cooling mode from 25 to 35oC.  

46.5 kW

at air temperature at air conditioner inlet 27oC, water temperature at condenser inlet 25oC, water flow rate 10 m3/h. Air flow rate through air cooler 10000 m3/h. Heating capacity 28.5 kW.

Coolant – R22.

 

18.0 kW.

h. 2KCA-20 the same the same the same 20 kW

at air temperature at air conditioner inlet 27oC, water temperature at condenser inlet 25oC, water flow rate 6 m3/h. Air flow rate through air cooler 4100 m3/h. Heating capacity 13 kW.

Coolant – R22.

 

10.5 kW.

i. 2KCA-15 the same the same the same 15 kW

at air temperature at air conditioner inlet 27oC, water temperature at condenser inlet 25oC, water flow rate 4 m3/h. Air flow rate through air cooler 4100 m3/h. Heating capacity 13 kW.

Coolant – R22.

 

8 kW.

j. KA2-25 the same the same Ambient air temperature 5 to 40oC. Air temperature at air conditioner inlet in cooling mode 25 to 35oC.  

29.1 kW

at air temperature at air conditioner inlet 27oC, Air temperature at condenser inlet 30oC, condenser cooling air flow rate 19000 m3/h. Air flow rate through air cooler 6000 m3/h. Heating capacity 25.5 kW.

Coolant – R22.

 

13.6 kW.

k. KA1-40 Self-contained air conditioner  

the same

Ambient air temperature 5 to 40oC. Water temperature at conditioner inlet up to 33oC, air temperature at air conditioner inlet not less than 25oC.

 

 

46.5 kW

at air temperature at air conditioner inlet 27oC, water temperature at condenser inlet 25oC, water flow rate 10 m3/h. Air flow rate through air cooler 10000 m3/h. Heating capacity 28.5 kW.

Coolant – R22.

 

18 kW.

l. KA2-40 the same the same Ambient air temperature 5 to 40oC. Water temperature at conditioner inlet up to 35oC, air temperature at air conditioner inlet not less than 25oC.

 

 

46.5 kW

at air temperature at air conditioner inlet 27oC, water temperature at condenser inlet 30oC, condenser cooling air flow rate 1900 m3/h. Air flow rate through air cooler 10000 m3/h. Heating capacity 28.5 kW.

Coolant – R22.

 

21.1 kW.

m. KCA-25 the same Designed for air conditioning in summer time, used for cooling, humidification and air purification from dust in industrial buildings.  

Ambient air temperature 5 to 40oC. Water temperature at condenser inlet up to 33oC, air temperature at air conditioner inlet not less than 25oC.

 

 

29.1 kW

at air temperature at air conditioner inlet 27oC, water temperature at condenser inlet 25oC, water flow rate 6 m3/h. Air flow rate through air cooler 6000 m3/h.

Coolant – R22.

 

11.4 kW.

n. KCA-45 the same the same the same 46.5 kW

at air temperature at air conditioner inlet 27oC, water temperature at condenser inlet 25oC, water flow rate 10 m3/h. Air flow rate through air cooler 10000 m3/h.

Coolant – R22.

 

18.0 kW.

o. KCA-15 the same the same the same 15 kW

at air temperature at air conditioner inlet 27oC, water temperature at condenser inlet 25oC, water flow rate 4 m3/h. Air flow rate through air cooler 4100 m3/h.

Coolant – R22.

 

7.9 kW.

p. KCA-20 the same the same Ambient air temperature 5 to 40oC. Water temperature at conditioner inlet 1 to 33oC, air temperature at air conditioner inlet not less than 25oC.

 

 

20 kW

at air temperature at air conditioner inlet 27oC, water temperature at condenser inlet 25oC, water flow rate 6 m3/h. Air flow rate through air cooler 4100 m3/h.

Coolant – R22.

 

10.5 kW.

q. 1KCA-15 the same the same Ambient air temperature 5 to 40oC, air temperature at air conditioner inlet not less than 25oC.  

15 kW

at air temperature at air conditioner inlet 27oC, air temperature at condenser inlet 30oC and its flow rate 12600 m3/h. Air flow rate through air cooler 4100 m3/h.

Coolant – R22.

 

11 kW.

r. 1KCA-20 the same the same the same 20 kW

at air temperature at air conditioner inlet 27oC, air temperature at condenser inlet 30oC and its flow rate 12600 m3/h. Air flow rate through air cooler 4100 m3/h.

Coolant – R22.

 

13 kW.

s. 3KCA-15 the same Designed for all the year round comfort air conditioning, used for cooling, heating, humidification and air purification from dust in industrial buildings.  

the same

15 kW

at air temperature at air conditioner inlet 27oC, air temperature at condenser inlet 30oC and its flow rate 12600 m3/h. Air flow rate through air cooler 4100 m3/h, heating capacity 13 kW.

Coolant – R22.

 

11 kW.

t. 3KCA-20 the same the same the same 20 kW

at air temperature at air conditioner inlet 27oC, air temperature at condenser inlet 30oC and its flow rate 12600 m3/h. Air flow rate through air cooler 4100 m3/h.

Coolant – R22.

 

13 kW.

11AT9 Thermocompressors
a. TXU6-4-0 Thermal refrigerating plant ( water-to-water type thermocompressor ). For water cooling used as intermediate coolant for milk cooling and simultaneously water heating for processing purposes on dairy farms. Coolant temperature at evaporator outlet 1 to 25oC, quantity of circulating coolant 3 to 5 m3/h, water temperature at condenser inlet 8 to 60oC. Refrigerating capacity 6.62 kW, heating capacity 8 kW at: coolant temperature at evaporator outlet 2oC, quantity of circulating coolant 3 m3/h, condensing temperature 10oC.

Coolant – R142

2.65

( without pumps )

b. TXU24-4-0 the same the same Coolant temperature at evaporator outlet 1 to 25oC, quantity of circulating coolant 1.5 to 6 m3/h, water temperature at condenser inlet 8 to 60oC. Refrigerating capacity 24.4 kW, heating capacity 29.5 kW at: coolant temperature at evaporator outlet 2oC, quantity of circulating coolant 12 m3/h, condensing point 40oC.

Coolant – R142

10.8

( without pumps ).

c. TXU50-2-0 Mobile thermal refrigerating plant. For drying and cooling of agricultural products, air conditioning in cattle-breeding and other buildings drying and heating of premises during construction.   Refrigerating capacity 44 kW, heating capacity 60 kW, at air temperature at air cooler inlet 20oC, air relative humidity at air cooler inletb85% and air flow rate through air cooler 3.16 m3/S.

Drying capacity 30 kg/h.

Coolant – R22.

18
d. HKB60-2-8 "Air-to-water" type thermocompressor. Designed for heating and hot water supply of living accommodation, production premises, housing for live-stock and hothouses. Boiling temperature

–25oC to 0oC, air temperature at air cooler inlet –15 to 15oC.

Heating capacity 60 kW

( 51600 Kcal/h ) at water temperature at condenser outlet 45oC and its flow rate 10 m3/h, air temperature at air cooler inlet 2oC, air flow rate 20000 m3/h.

Coolant – R22.

24
e. HT22-1-0 "Air-to-air" type thermocompressor. Designed for operation as a part of CKTH-800 type plant for drying of soft and leaf-bearing wood lumber. Boiling temperature

0oC to 4oC, air temperature at air cooler inlet

25 to 35oC.

Refrigerating capacity 22 kW, heating capacity 27 kW at to=2, tk=50oC.

Coolant – R12

Electric heater 13 kW, 2 pcs.

15
f. HKT5-4-9 "Water-to-water" type thermocompressor. For use in consumers heat supply systems

( heating, production process ).

 

Heat-transfer agent temperature at evaporator inlet 20 to 50oC.

Heating capacity 16 kW at oil temperature at evaporator inlet 40oC, oil quantity circulating through evaporator 7.0

m3/h and water temperature at condenser outlet 60oC.

Coolant – R142.

 

4.1

g. HKT10-4-9 the same the same the same Heating capacity 40 kW at oil temperature at evaporator inlet 40oC, oil quantity circulating through evaporator 14.0

m3/h, water temperature at condenser outlet 60oC.

Coolant – R142.

 

8.3

11AT10 Air coolers.
Code Mark Name Purpose Working range Basic characteristics Power consumption at nominal conditions kW. Net mass

kg

Overall dimensions

length, mm

width, mm

height, mm

a. VO10-2-0 Marine air coolers.  

For air cooling in marine provision chambers.

 

Boiling temperature 5oC to –10oC.

Heat exchange surface F=9m2.

Air flow rate 1500 m3/h.

0.2 34 650

΄ 365

΄ 598

b. VO-20-2-0 the same the same the same F=18m2.

Air flow rate 2600 m3/h.

0.4 57 1070

΄ 365

΄ 598

c. VO-30-2-0 the same the same the same F=27m2.

Air flow rate 3250 m3/h.

0.4 70 1070

΄ 365

΄ 748

d. VO-10H-2-2 the same the same Boiling temperature

-40oC to

–10oC.

F=9m2.

Air flow rate 1350 m3/h.

0.2 heater 2.4 37.5 682

΄ 365

΄ 632

e. VO-20H-2-2 the same the same the same F=18m2.

Air flow rate 2450 m3/h.

0.4 heater

3.8

66 1100

΄ 365

΄ 632

f. VO-30H-2-2 the same the same the same F=27m2.

Air flow rate 3100 m3/h.

0.4 heater 3.8 76 1100

΄ 365

΄ 782

g. VOG-5 Air coolers For air cooling as a part of refrigerating machines and air conditioners. Boiling temperature 5oC to –10oC. Heat load Q0 at

t = 12oC,

t = t1 – to, where

to – boiling temperature.

t1 – air temperature at air cooler inlet Qo = 1.5 kW

F = 5.0 m2.

0.07 5.6 530

΄ 672

΄ 240

h. VOG-20 the same the same the same Qo = 3.0 kW

F = 20.5 m2.

0.087 30.6 1014

΄ 684

΄ 394

 

i.

VOG-31 the same the same the same Qo = 4.5 kW

F = 31.4 m2.

0.128 42.7 1414

΄ 734

΄ 394

 

j.

VOG-40 the same the same the same Qo = 6.0 kW

F = 39.2 m2.

0.16 52.5 1694

΄ 764

΄ 394

k. VOG-50 the same the same the same Qo = 8.0 kW

F = 49.6 m2.

0.255 59.6 1994

΄ 814

΄ 394

l. VOG-20 TEH the same the same Boiling temperature

-10oC to

-40oC.

 

Defrosting power

N = 4.0 kW

Qo = 3.0 kW

F = 20.5 m2.

0.087 32 1014

΄ 684

΄ 394

m. VOG-31

TEH

the same the same the same N = 6.3 kW

Qo = 4.5 kW

F = 31.4 m2.

0.128 44 1414

΄ 734

΄ 394

n. VOG-40

TEH

the same the same the same N = 8.0 kW

Qo = 6.0 kW

F = 39.2 m2.

 

0.16

54 1694

΄ 764

΄ 394

o. VOG-50

TEH

the same the same the same N = 10.0 kW

Qo = 8.0 kW

F = 49.6 m2.

0.255 61 1994

΄ 814

΄ 394

11AT11 Mechanical-draft tower.
Code Mark Name Purpose Working range Basic characteristics. Power consumption at nominal conditions, kW. Overall dimensions.

length, mm

width, mm

height, mm.

a. GV40 Mechanical-draft tower. For cooling circulating water feed to refrigerating machine condenser. Ambient air temperature

-30 to 40oC.

Heat load 46.5 kW ( at water flow rate 10 m3/h, wet-bulb air temperature

20.5oC and relative humidity 40% ).

1.1 1650

΄ 850

΄ 2240

11AT12 Air condensers.
a. KVG-23 Horizontal air condensers. For coolant condensation.. Ambient air temperature 5 to 45oC. Heat load QT at

D t = 15oC,D t = tk – tb where

tk – condensation point

tb – air temperature at condenser inlet

QT = 5.8 kW

P max. work 20 kgf/cm2.

F = 24.03 m2.

0.25 760

΄ 694

΄ 978

b. KVG-40 the same the same the same QT = 10.3 kW

P max. work 20 kgf/cm2.

F = 38.5 m2.

 

0.28

830

΄ 698

΄ 1040

c. KVG-55 the same the same the same QT = 14 kW

P max. work 20 kgf/cm2.

F = 55 m2.

0.5 1375

΄ 697

΄ 978

d. KVG-80 the same the same the same QT = 20.6 kW

P max. work 20 kgf/cm2.

F = 76 m2.

0.56 1390

΄ 698

΄ 1040

e. KVG-100 the same the same the same QT = 25 kW

P max. work 20 kgf/cm2.

F = 100 m2.

1.12 1370

΄ 1416

΄ 1034

f. KVG-120 the same the same the same QT = 31 kW

P max. work 20 kgf/cm2.

F = 120 m2.

0.75 1955

΄ 702

΄ 1045

g. KVG-160 the same the same the same QT = 42 kW

P max. work 20 kgf/cm2.

F = 160 m2.

1.15 1950

΄ 1416

΄ 1034

h. KVG-230 the same the same the same QT = 60 kW

P max. work 20 kgf/cm2.

F = 230 m2.

1.16 2260

΄ 1732

΄ 1016

i. KVV-55 the same Vertical air condensers. the same QT = 14 kW

P max. work 20 kgf/cm2.

F = 55 m2.

0.56 1275

΄ 370

΄ 755

j. KVV-80 the same the same the same QT = 20.6 kW

P max. work 20 kgf/cm2.

F = 76 m2.

0.56 1275

΄ 430

΄ 755

k. KVV-100 the same the same the same QT = 25 kW

P max. work 20 kgf/cm2.

F = 100 m2.

1.12 1555

΄ 430

΄ 755

11AT13 Ammonia units.
Code Mark Name Purpose Working range Basic characteristics.
Refrigerating capacity, kW

( Kcal/h ).

Power consumption at nominal conditions, kW.
a. AK26-7-2 Piston compressor unit. Designed for operation as a part of industrial ammonia refrigerating machines.

Coolant – NH3.

Boiling temperature

-15 to –30oC.

26 ( at boiling temperature

–15oC, condensation point

tc = 30oC ).

18.5
b. 2A50-7-1 Screw compressor unit. the same Boiling temperature

-5 to –20oC.

52.8 ( at boiling temperature

–15oC, condensation point

tc = 30oC ).

15.47
c. 2A140-7-3 the same the same Boiling temperature

-10 to –35oC.

114 ( at boiling temperature

–15oC, condensation point

tc = 30oC ).

37.4
d. 2A140-7-1 the same the same Boiling temperature

5 to –15oC.

264 ( at boiling temperature

–15oC, condensation point

tc = 30oC ).

48
e. 2A840-7-3 the same the same Boiling temperature

-10 to –30oC.

840 ( at boiling temperature

–15oC, condensation point

tc = 30oC ).

168
11A14 Ammonia machines.
a. MKT26-7-2 Refrigerating machine. Designed for cooling intermediate coolant.

Coolant – NH3.

Boiling temperature

-15 to –30oC.

26 at to = -15oC, water temperature at condenser inlet up to 33oC. 18.5
11AT15 Evaporator condenser units and apparatus used for operation with ammonia.
Code Mark Name Purpose Design condition. Installed power Heat flow, kW Heat exchange surface, m2 Net mass, kg Overall dimensions

length, mm

width, mm

height, mm

Evaporator. Condenser
a. BIKPL 140-7-3 Plate-type evaporator condenser unit. Designed for operation as a part of ammonia refrigerating plants.

Coolant – aqueous solution CaCl2. Condenser cooling medium-pure service water.

Coolant temperature at evaporator outlet –10oC, water temperature at condenser inlet 25oC. - 140 58 34 3650 2662

΄ 836

΄ 2993

b. BIKPL 280-7-3 the same the same the same - 280 116 68 4674 2762

΄ 886

΄ 3018

c. BIKPL 420-7-3 the same the same the same - 420 172 102 5737 2864

΄ 938

΄ 3043

d. BIKPL 250-7-1 the same Designed for operation as a part of ammonia refrigerating plants.

Coolant –service water.

Condenser cooling medium-pure service water.

 

Coolant temperature at evaporator outlet 2oC, water temperature at condenser inlet 25oC.

- 250 100 63 4564 3462

΄ 836

΄ 2993

e. BIKPL

500-7-1

the same the same the same - 500 200 126 6380 3562

΄ 886

΄ 3018

f. BIKPL

750-7-1

the same the same the same - 750 300 189 8248 3664

΄ 938

΄ 3043

g. MX4.5

MX6

MX9

MX12

MX18

oil coolers Designed for operation as a part of ammonia and freon refrigerating plants with screw compressors. Oil temperature at oil cooler inlet up to 90oC, working pressure up to 2.0 MPa, water temperature at oil cooler inlet 30oC, working pressure 0.6 MPa. - -

4.5

6.0

9.0

12.0

18

130

175

215

340

420

1165΄ 500

1665΄ 500

2165΄ 500

1665΄ 850

2165΄ 850

i. KVPI-50.000 Vertical panel evaporator condenser. Designed for operation as a part of ammonia refrigerating plants.

Condenser cooling medium-pure service water.

Condensation point 35oC. 2.2 152 - 50 4000 1720

΄ 1735

΄ 4260

 

Code Technical characteristics of the equipment. Technological application. Price, USD
11AT16 UXV30-2-2 Refrigerating plant.

Designed for vine cooling and vine material cold treatment, provide acceleration of ripening process, improving teste in a short

time, vine brightening, precipitation of tartrate solt, exclude growth of fungus diseases.

                                                                stage 1                       stage2

Technical characteristics:                   IMVT25-2-2              IMVT17-2-2

Refrigerating capacity,

kW ( Kcal/h )                                       33 ( 28380 )             10.5 ( 9030 )

Power consumption, kW                            12.55                           6.65

Quantity of vine material cooled in 18-hours period, m3 - 18

upon receipt of the inquiry
11BJ1 Screw compressors for industrial refrigerating installations

Specifications:

upon receipt of the inquiry
Compressor
type
Compressible
medium
Refrigerating power, kW
at boiling temperature
Maximum
consumed
power,
kW
Cooling
water
flow
rate,
m3/h
from -10°C
to +5°C
and at the
condensation
temperature
of +40°C
from -25°C
to -10°C
and at the
condensation
temperature
of +35°C
-40°C
and at the
condensation
temperature
of -10°C
21ΐ410-7-1 Ammonia 498 - 958 - - 200 10
21ΐ410-7-3 Ammonia - 237 - 484 - 160 15
21ΐ410-7-7 Ammonia - - 166 75 6
21ΐ200-7-3 Ammonia - 208 - 75 8
21ΐD160-7-5 Ammonia - 168 168 98 30

A list of the components - upon receipt of the inquiry.

Go to the list.

Rambler's Top100